LeukoComplete™ Gene Detection Kit for human ACTB
Cosmo Bio
- Catalog No.:
- MIN-11150-HC-001
- Shipping:
- Calculated at Checkout
Primer and Enzyme for Real-Time PCR
LeukoComplete™ Cellular Immunity Detection Kit
This unique research-use test kit adds antigens (e.g., viral peptide fragments) to a small amount of whole blood and uses a dedicated plate to evaluate gene expression changes in stimulated T cells via qPCR. It is designed for human samples.
Features
This kit extracts and purifies mRNA from white blood cells (including T cells) in whole blood, followed by cDNA synthesis. The resulting cDNA can be analyzed by qPCR to evaluate relative gene expression changes. It supports the Ex vivo Activation of Gene in Leukocyte (EAGL) method and includes two proprietary plates—“Leukocyte Isolation Plate” and “mRNA Capture Plate”—for high throughput and reproducibility.
Specifications
Applications |
|
---|---|
Work time | 180 minutes + antigen stimulation time |
Sample Types |
|
Final Product | 30 µL cDNA |
Detection Targets |
Control genes (human, mouse): ACTB, GAPDH, B2M Target genes (human): IFNG, IL-2, TNFSF2, IL-6, IL-10, GM-CSF, CXCL10, IL-4, IL-5 Target genes (mouse): IFNG, IL-10, IL-17 |
Measuring Equipment |
|
Use Cases |
|
Kit Components
LeukoComplete™ Plate and RT Kit (Cat. No. 11130)
Component | Size |
---|---|
PT Buffer | 15 mL × 1 bottle |
Leukocyte Isolation Plate (Filter) | 1 sheet |
Deep Well Plate | 1 sheet |
Proteinase K | 30 µL × 1 |
TCEP | 300 µL × 1 |
Lysis Buffer | 6 mL × 1 bottle |
mRNA Capture Plate | 1 sheet |
Wash Buffer A | 30 mL × 1 bottle |
Wash Buffer B | 50 mL × 1 bottle |
Aluminum Seal | 1 sheet |
M-MLV Reverse Transcriptase | 40 µL × 1 |
RNase Inhibitor | 10 µL × 1 |
RT Buffer | 1.5 mL × 2 |
LeukoComplete™ Antigen Coated Plate (Cat. No. 11140)
Component | Size |
---|---|
Antigen Coated Plate for SARS-CoV-2 | 1 sheet (24 tests) |
* Overlapping peptides (15-mers with 11 aa overlap) from the SARS-CoV-2 spike protein are used as antigens. Each test includes four wells: a blank, two antigens, and a positive control.
LeukoComplete™ Gene Detection Kit
Component | Size |
---|---|
Primer Mix * | 100 µL × 1 |
PCR Enzyme Mix | 500 µL × 1 |
* Part number and Primer Mix content vary by target gene.
Product Data
Gene Extraction Performance
Figure 1: High correlation (R² > 0.9) was observed between sample concentration and expression levels for human blood, PBMC, mouse spleen, and mouse blood.

Target Gene Expression Over Time
Figure 2: Expression of IFNG, IL2, IL4, and GM-CSF genes in fresh human blood (n=4) exposed to antigen (CEF peptides) over time. log₂FC = ΔΔCt using control genes for normalization.

Comparison of Cellular Immunity Assays
Figure 3: Comparison between LeukoComplete™, ELISpot, and ICS in vaccinated subjects. LeukoComplete™ showed comparable or better sensitivity for IFNG detection.

Analysis Method
Figure 4: Relative gene expression evaluated using the Comparative Ct (ΔΔCt) method: ΔΔCt = (Ct_target - Ct_control) [with antigen] - (Ct_target - Ct_control) [without antigen]

Reagent Abbreviations
Reagent | Abbreviation |
---|---|
Phorbol 12-myristate 13-acetate | PMA |
Ionomycin | IM |
Phytohemagglutinin | PHA |
Lipopolysaccharide | LPS |
Concanavalin A | ConA |
CEF control peptide pool | CEF |
Expression Ranking
Rank | Mean Relative mRNA Expression (log₂FC, n=12) |
---|---|
+++ | > 8 |
++ | 5 – 8 |
+ | 3 – 5 |
+/- | 1.5 – 3 |
N.D. | < 1.5 |
- | Not evaluated |
References
- Mitsuhashi M, Tomozawa S, Endo K, Shinagawa A. Quantification of mRNA in whole blood by assessing recovery of RNA and efficiency of cDNA synthesis. Clin Chem. 2006;52(4):634–42.
- Mitsuhashi M. Ex vivo simulation of leukocyte function: stimulation of specific subset of leukocytes in whole blood followed by the measurement of function-associated mRNAs. J Immunol Methods. 2010;363(1):95–100.
- Saito et al. Rapid and high throughput assessment of cellular immunity against SARS-CoV-2 using the ex vivo gene activation method. Biochem Biophys Res Commun. 2023. doi: https://doi.org/10.1016/j.bbrc.2023.149398
Note
This product is a research reagent. Do not use for medical, diagnostic, or food-related purposes in humans or animals.
Product Specifications | |
Reactivity | Human |
Documents & Links for LeukoComplete™ Gene Detection Kit for human ACTB | |
Datasheet | LeukoComplete™ Gene Detection Kit for human ACTB Datasheet |
Documents & Links for LeukoComplete™ Gene Detection Kit for human ACTB | |
Datasheet | LeukoComplete™ Gene Detection Kit for human ACTB Datasheet |